Quantities of Materials Required for Testing
|
Test |
|
Description |
|
Quantity Required |
|
|
|
Waterstops and Gate Seals |
|
|
|
CRD-C 513 |
|
Rubber Waterstop and Gate Seals, a. Full evaluation, initial 60 m (200 lineal ft) b. Tensile strength and elongation, each additional 60 m (200 ft) c. Job-made splices |
|
1.2 m (4 ft) 1.2 m (4 ft) 1 sample |
|
CRD-C 572 |
|
Polyvinyl Chloride Waterstops a. Full evaluation, initial 60 m (200 lineal ft) b. Tensile strength and elongation, each additional 60 m (200 ft) c. Job-made splices |
|
1.2 m (4 ft) 1.2 m (4 ft) 1 sample |
|
|
|
Joint Fillers |
|
|
|
CRD-C 507 (TT-C-00598C)* CRD-C 506 (TT-S-00227E)* CRD-C 541 (TT-S-230a)* CRD-C 542 (TT-S-001543A)* CRD-C 543 (TT-S-001657)* |
|
All Caulking and Sealing Compounds, for large bulk containers, composite sample from top, middle, & bottom For small lots of material, Federal Test Method Standard No. 141 |
|
1 L (1 qt) Method 1021 |
|
CRD-C 508 (ASTM D 1751) |
|
Preformed Expansion Joint Filler (Non-extruding and Resilient Bituminous Types)(per 93 m2 (1000 ft2)) |
|
0.2 m2 (2 ft2) |
|
CRD-C 509 (ASTM D 1752) |
|
Preformed Sponge Rubber & Cork Expansion Joint Fillers (per 93 m2 (1000 ft2)) |
|
0.2 m2 (2 ft2) |
|
CRD-C 531 (ASTM D 2628) |
|
Preformed Polychloroprene Elastomeric Joint Seals If less than 2.5 cm (1 in) width |
|
2.8 m (9 lin ft) 3.7 m (12 lin ft) |
|
CRD-C 532 (ASTM D 2835) |
|
Adhesive - Lubricant for Installation of Preformed Joint Seals in Concrete Pavements |
|
1 L (1 qt) |
|
ASTM C 994 |
|
Preformed Expansion Joint Filler for Concrete, Bituminous Type (per 93 m2 (1000 ft2)) |
|
387 cm2 (60 in2) |
|
TT-P-0791B* |
|
Putty, Linseed-Oil Type, for large bulk containers, composite sample from top, middle & bottom For small lots of material, Federal Test Method Standard No. 141 |
|
1 L (1 qt) Method 1021 |
|
Test |
|
Description |
|
Quantity Required |
|
|
|
Joint Sealers |
|
|
|
CRD-C 506 (TT-S-00227E)* |
|
Elastomeric Type, Multi-component (Buildings & Other Structures)(each component and lot) (include sufficient primer) |
|
8 L (8 qt) |
|
CRD-C 526 (SS-S-200E)* |
|
Elastomeric Polymer Type, Two-Component, Jet Fuel Resistant, Cold Applied (each component and lot) (include sufficient primer) |
|
8 L (8 qt) |
|
CRD-C 530 (SS-S-1401C)* |
|
Hot Applied, for Concrete and Asphalt Pavements (each lot) |
|
8 L (8 qt) |
|
SS-S-1614A* |
|
Sealing Compound, Jet Fuel Resistant, Hot Applied, One Component, for Portland Cement and Tar Concrete Pavements (each lot) |
|
8 L (8 qt) |
|
Test |
|
Description |
|
Quantity Required |
|
|
|
|
|
|
|
CRD-C 592 (ASTM D 558) |
|
Moisture Density |
|
3 kg (7 lb) |
|
CRD-C 593 (ASTM D 559) |
|
Wetting and Drying |
|
3 kg (7 lb) |
|
CRD-C 594 (ASTM D 560) |
|
Freezing and Thawing |
|
3 kg (7 lb) |
|
-- |
|
Compressive and Tensile Splitting Strengths |
|
As specified |
|
Test |
|
Description |
|
Quantity Required |
|
CRD-C 401 |
|
Water for Curing, Stain Test |
|
3 L (3 qt) |
|
CRD-C 402 CRD-C 403 CRD-C 404 CRD-C 405 |
|
Chemical Analysis |
|
1 L (1 qt) |
|
CRD-C 407 (ASTM C 932) |
|
Test for Iron Bacteria |
|
1 L (1 qt) |
|
ASTM D 993 |
|
Test for Sulfate-Reducing Bacteria |
|
1 L (1 qt) |
|
Test |
|
Description |
|
Quantity Required |
|
ASTM C 80 |
|
Water Retentivity of Masonry Mortar |
|
160 |
|
ASTM C 476 |
|
Reinforced Masonry Mortar Mixture Proportioning |
|
570 |
|
|
|
Common Brick |
|
|
|
CRD-C 605 (ASTM C 55) |
|
Concrete Building Brick (per lot) |
|
3 |
|
ASTM C 62 |
|
Building Brick (Solid Masonry, Clay, or Shale)(per 50,000 bricks) |
|
10 |
|
ASTM C 73 |
|
Calcium Silicate Face Brick (per 50,000 bricks) |
|
10 |
|
ASTM C 216 |
|
Facing Brick (per 50,000 bricks) |
|
10 |
|
|
|
Paving Bricks and Blocks |
|
|
|
ASTM C 7 |
|
Paving Brick (per 50,000 bricks) |
|
10 |
|
ASTM C 902 |
|
Pedestrian and Light Traffic Paving Brick (per 50,000 bricks) |
|
25 |
|
-- |
|
Concrete Paving Block (per 50,000 blocks) |
|
12 |
|
|
|
Refractory Bricks |
|
|
|
CRD-C 20 (ASTM C 666) |
|
Resistance to Freezing and Thawing |
|
5 |
|
ASTM C 24 |
|
Pyrometric Cone Equivalent |
|
5 |
|
ASTM C 113 |
|
Reheat Change of Refractory Bricks |
|
3 |
|
ASTM C 133 |
|
Cold Crushing Strength and Modulus of Rupture of Refractory Bricks and Shapes (min.) |
|
5 |
|
ASTM C 134 |
|
Size and Bulk Density of Refractory Bricks and Insulating Fire Brick |
|
10 |
|
ASTM C 154 |
|
Warpage of Refractory Brick, or Deviation from a Plane Surface |
|
20 |
|
-- |
|
Coefficient of Thermal Expansion |
|
5 |
|
-- |
|
For All Specification Tests |
|
25 |
|
|
|
|
|
|
|
Test |
|
Description |
|
Quantity Required |
|
|
|
Tile |
|
|
|
ASTM C 34 |
|
Structural Clay Load-Bearing Wall Tile (each kiln or lot) |
|
5 |
|
ASTM C 56 |
|
Structural Clay Nonload-Bearing Tile (each kiln or lot) |
|
5 |
|
ASTM C 57 |
|
Structural Clay Floor Tile (each kiln or lot) |
|
5 |
|
ASTM C 126 |
|
Ceramic Glazed Structural Clay Facing Tile, Facing Brick, and Solid Masonry Units (each additional 30,000 units) |
|
1,000 10 |
|
|
|
Concrete Masonry |
|
|
|
CRD-C 73 (ASTM C 426) |
|
Dry Shrinkage of Concrete Block (half-face shells) |
|
3 |
|
CRD-C 76 (ASTM C 427) |
|
Moisture Condition by the Relative Humidity Method |
|
As specified |
|
CRD-C 606 (ASTM C 90) |
|
Hollow Load-Bearing Units (10,000 units) (10,000 units and greater) |
|
10 20 |
|
CRD-C 607 (ASTM C 129) |
|
Nonload-Bearing Units (10,000 units) (10,000 units and greater) |
|
10 20 |
|
CRD-C 608 (ASTM C 145) |
|
Solid Load-Bearing Units (10,000 units) (10,000 units and greater) |
|
10 20 |
|
|
|
Masonry Mortars |
|
|
|
CRD-C 602 (ASTM C 144) |
|
Aggregate for Masonry Mortar |
|
15 kg (33 lb) |
|
CRD-C 609 (ASTM C 67) |
|
Efflorescence adapted for Mortars |
|
As Specified |
|
CRD-C 618 (ASTM C 270) |
|
Unit Masonry Mortar Mixture Proportioning |
|
As Specified |
|
ASTM C 80 |
|
Water Retentivity |
|
As Specified |
|
ASTM C 476 |
|
Reinforced Masonry Mortar Mixture Proportioning |
|
As Specified |
|
Test |
|
Description |
|
Quantity Required |
|
|
|
|
|
|
|
CRD-C 501 (ASTM A 615) |
|
Deformed and Plain Billet Steel Bars for Concrete Reinforcement (each heat) |
|
2 |
|
CRD-C 502 (ASTM A 616) |
|
Rail Steel Deformed and Plain Bars for Concrete Reinforcement (9071 kg (10 ton) lots) |
|
2 |
|
CRD-C 503 (ASTM A 416) |
|
Uncoated Seven-Wire Stress-Relieved Strand for Prestressed Concrete (18142 kg (20 ton) lots) |
|
2 |
|
CRD-C 510 (ASTM A 185) |
|
Welded Steel Wire Fabric for Concrete Reinforcement |
|
0.1 m2 (1.1 ft2) |
|
CRD-C 519 (ASTM A 617) |
|
Axle Steel Deformed Bars for Concrete Reinforcement (9071 kg (10 ton) lots) |
|
2 |
|
CRD-C 520 (ASTM A 82) |
|
Cold-Drawn Steel Wire for Concrete Reinforcement (9071 kg (10 ton) lots) |
|
2 |
|
CRD-C 523 (ASTM A 421) |
|
Uncoated Stress-Relieved Wire for Prestressed Concrete (each 10 coils per lot) |
|
1 |
|
CRD-C 524 (ASTM A 322) |
|
Hot Rolled Alloy Steel Balls |
|
As specified |
|
CRD-C 562 (ASTM A 184) |
|
Fabricated Steel Bar or Rod Mats for Concrete Reinforcement (each 1000 mats) |
|
2 |
|
ASTM A 370 |
|
Steel Products (Mechanical Tests) |
|
As specified |
|
-- |
|
Splices and Welds |
|
As specified |
|
-- |
|
Noncorrosive Wire Reinforcing Fabric |
|
As specified |
|
-- |
|
Certification of Threaded Restraining Rods (per lot) |
|
3 |
|
-- |
|
All Other Types of Metals and Test Procedures |
|
As specified |
|
|
|
|
|
|
|
Test |
|
Description |
|
Quantity Required |
|
|
|
|
|
|
|
SS-T-312* |
|
Asphalt, Rubber, Vinyl, & Vinyl Asbestos Tile (per 10,000 of each type, color, or size) |
|
20 |
|
MMA-A-110* |
|
Adhesive, Asphalt, Cutback Type |
|
4 L (4 qt) |
|
MMM-A-115* |
|
Adhesive, Asphalt, Water Emulsion Type |
|
4 L (4 qt) |
|
ASTM C 57 |
|
Clay Tile (each kiln or each 90718 kg (100 ton)) |
|
5 |
|
-- |
|
All Other Tiles and Adhesives |
|
As specified |
|
|
|
|
|
|
|
-- |
|
Lubricating Oil |
|
As specified |
|
-- |
|
Insulating (Transformer) Oil |
|
As specified |
|
|
|
|
|
|
|
SS-R-501* SS-R-630* HH-R-595* |
|
Roofing Felts |
|
As specified |
|
SS-S-298* SS-S-300* |
|
Shingles |
|
As specified |
|
ASTM C 312 (SS-A-701)* ASTM D 449 (SS A 666)* |
|
Asphalt |
|
1 L (1 qt) |
|
R-P-381* |
|
Pitch and Coal Tar |
|
1 L (1 qt) |
|
|
|
|
|
|
|
Test |
|
Description |
|
Quantity Required |
|
|
|
|
|
|
|
CRD-C 300 |
|
Curing Compound |
|
As specified |
|
CRD-C 316 (TT-T-291E)* |
|
Solvent |
|
2 L (2 qt) |
|
CRD-C 532 (ASTM D 2835) |
|
Lubricant for Preformed Pavement Seals (each lot) |
|
1 L (1 qt) |
|
CRD-C 590 MMM-G-650a* CRD-C 591 MMM-B-350B* |
|
Epoxy Resin Binder or Grout (each component) |
|
2 L (2 qt) |
|
CRD-C 621 |
|
Non-shrink Grout (minimum of 1 package) |
|
0.03 m3 (1 ft3) |
|
ASTM C 881 |
|
Epoxy-Resin Base Bonding Systems (each component) |
|
2 L (2 qt) |
|
-- |
|
Mineralogy and Microstructure of Soils, Clays, Site Rocks, and Masonry Units |
|
As specified |
* Federal Specification Standard